EKB500_ma_en_rev1.04 13
System settings required for startup:
DVR:
MENU > RS232/RS485:
RS485
BAUDRATE 9600 BPS > Baudrate must be the same as baudrate of
the respective EKB 500 port (default setting
for both keyboard and DVR is 9600)
STOPBIT 1
PARITY NONE
DATABIT 8
RS232/RS485 ID 1 > RS-485 address must correspond to
DVR setting in EKB 500 menu
EKB-500: (for details, please refer to "8. Menu settings")
DVR setting:
MENÜ ("SHIFT" + "MENU" key) > DEVICE SETTING > DVR SETTING:
DVR NAME: Selectable DVR number (independent of RS-485 address)
RS485 CONNECTED TO PORT: _ : RS-485 port to which the DVR is connected (1 or 2)
RS485 Adress: DVR RS-485 address
(complies with DVR menu "RS232/RS485 ID")
Must be in accordance with DVR setting
DVR xxxx changed Press ENTER key to confirm the settings
[ENT] to save
MENÜ > COM PORT SETTING:
Port:_ (1 or 2) Enter the RS-485 port to which the DVR is connected
Input the Port (1 or 2 )
BAUD: 9600< Baudrate setting (according to DVR)
Protocol: EFV1 Protocol type, setting irrelevant for DVR control> ENTER
Port: 1 Changed Press ENTER key to confirm the settings
[ENT] to save
For details and further settings (e.g. matrix monitor setup), please refer to menu description.