EDR910_1610_ma_en_rev1 00 - 49 -
3.11.4 HDD FULL
In operation mode HDD FULL: STOP (setting in RECORDING menu), the recording
process is stopped if the harddisk is full. Define the alarm reactions in this menu item:
(1) BUZZER: By selecting “ENABLE”, the buzzer is activated.
(2) ALARM OUTPUT: Output relay activation.
1 Output relay switches upon alarm.
NONE no output relay reaction upon alarm.
(3) ALARM DURATION: Alarm duration adjustment from 1~99 seconds or permanent
(4) NETWORK ALARM: YES: Network alarm activated (for settings refer to
NETWORK menu)
Network alarm reception requires optional
PowerCon software.
NO: No network alarm transmission
(5) EMAIL: YES: Alarm email transmission (for settings refer to
NETWORK menu).
NO: No email alarm transmission.
WARNING SETUP MENU
FAN FAULT BUZZER ENABLE
HDD TEMP. ALARM OUTPUT 1
NO HDD ALARM DURATION PERMANENT
HDD FULL NETWORK ALARM NO
EMAIL NO