NAV Series TCP/IP Standalone Network Access Controller
11
Figure 2-6
Note:AmongtheNo.7,9,11and13extensionwires,No.11extensionwireisthecommon
groundterminalofalarminput,doorstatusswitchanddooropenbutton.
2.2.2.4ConnectingtotheDoorOpenButton
The controller provides the interface of the door open button. The door open button is
connectedwiththeNo.9extensionwireonthebackplateofthecontroller,andtheground
terminalisconnectedwiththeNo.11extensionwire.
Figure 2-7
2.2.3 Connecting to the Alarm Input / Output
2.2.3.1ConnectingtotheFireAlarm/AlarmInput
Thecontrolleronlyprovidesonepathofalarminput(thealarminputcanbesettobefire
alarm input or other alarm input). The input terminal is connected with the No.7
extensionwireonthebackplateofthecontroller,andthegroundterminalisconnected
withtheNo.5extensionwire.
Figure 2-8
Alarm sensor
Alarm input
GND
5
7
Door open
9
11
Door status
switch
11
13