EverFocus Flex1.0 Manuel d'utilisateur Page 33

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 123
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 32
A System PIN Fail event will be generated when a user enters an incorrect PIN
three times consecutively when attempting to enter the system setting.
The controller generates alarm output(s) according to the settings in the
“System PIN Error” column.
Fig. 4.17 Alarm setting 2 tab
Arm PIN Fail:
An ARM PIN Fail event is generated when an incorrect ARM PIN is entered
three times consecutively.
The controller generates alarm output(s) according to the settings in the
“ArmZone PIN error” column.
Alarm In 0:
An Alarm In 0 event is generated when Alarm In 0 input is active.
The controller generates alarm output(s) according to the settings in the “Alarm
In 0” column.
Remote Alarm:
A System administrator can directly generate alarm signals using the control
software when he observes an abnormal condition through a surveillance
system.