Fig. 4.21 Other setting tab
Configure Fire Alarm Control
EverAccess software allows the user to choose which door to open and close during a
fire alarm.
The box next to “Door behavior under fire alarm:” allows the user to change the door
setting during a fire alarm. To change the setting:
Point and click to change each box representing a particular door in the
controller. A door can be closed or open.
O: the door is Fail safe and is opened in the event of a fire alarm.
C: the door is Fail secure and is closed in the event of a fire alarm.
Fig. 4.22 Set door behavior under fire alarm